Bathroom Vent Fans

Bathroom_fanYour bathroom vent fan could be causing damage to your home without you knowing it. Bathroom ventilation systems are designed to exhaust odors and moist air to the home’s exterior, but it may not be doing what you think. Typical systems consist of a ceiling fan unit connected to a duct that terminates at the roof.

Fan Function  

The fan may be controlled in one of several ways:

  • Most are controlled by a conventional wall switch.
  • A timer switch may be mounted on the wall.
  • A wall-mounted humidistat can be pre-set to turn the fan on and off based on different levels of relative humidity.

Ventilation systems should be installed in all bathrooms. This includes bathrooms with windows, since windows will not be opened during the winter in cold climates.

Defects

The following conditions indicate insufficient bathroom ventilation:

  • moisture stains on walls or ceilings;
  • corrosion of metal;
  • visible mold on walls or ceilings;
  • peeling paint or wallpaper;
  • frost on windows; and
  • high levels of humidity.

The most common defect related to bathroom ventilation systems is improper termination of the duct. Vents must terminate at the home exterior.

vent fan

The most common improper terminations locations are:

  • mid-level in the attic. These are easy to spot;
  • beneath the insulation. The duct may terminate beneath the insulation or there may be no duct installed; and
  • under attic vents. The duct should terminate at the home exterior, not just under it. The fact of the matter is that in the Hampton Roads area, even though it’s not right, they are just terminated to the underside of the attic vent. For that reason, we don’t write this up as a problem because it would be on every report, but the picture above, does get written up on a regular basis and in this case, we would also be writing up the wiring too.
  • As tempting as it may be, the vent should not discharge under the roof eave either as convection will take it right back into the attic.

Improperly terminated ventilation systems may appear to work fine from inside the bathroom, but up in the attic, it looks like the picture above. Sometimes, poorly installed ducts will loosen or become disconnected at joints or connections.

Ducts that leak or terminate in attics can cause problems from condensation. Warm, moist air will condense on cold attic framing, insulation and other materials. This condition has the potential to cause health and/or decay problems from mold, or damage to building materials, such as drywall. Moisture also reduces the effectiveness of thermal insulation. If there is a masonry chimney that goes through the attic, the moisture induced to the attic will condense on the chimney causing it to sweat.

Mold

Perhaps the most serious consequence of an improper ventilation setup is the potential accumulation of mold in attics or crawlspaces. Mold may appear as a fuzzy, thread-like, cobwebby fungus, although it can never be identified with certainty without being lab-tested. Health problems caused by mold are related to high concentrations of spores in indoor air.  Spores are like microscopic seeds, released by mold fungi when they reproduce. Every home has mold. Moisture levels of about 20% in materials will cause mold colonies to grow. Inhaling mold spores can cause health problems in those with asthma or allergies, and can cause serious or fatal fungal infections in those with lung disease or compromised immune systems.

Mold is impossible to identify visually and must be tested by a lab in order to be confidently labeled. Inspectors should refrain from calling anything “mold” but should refer to anything that appears as mold as a material that “appears to be microbial growth.” Inspectors should include in their report, and in the inspection agreement signed by the client, a disclaimer clearly stating that the General Home Inspection is an inspection for safety and system defects, not a mold inspection.

Decay, which is rot, is also caused by fungi. Incipient or early decay cannot be seen. By the time decay becomes visible, affected wood may have lost up to 50% of its strength.

In order to grow, mold fungi require the following conditions to be present:

  • oxygen;
  • temperatures between approximately 45° F and 85° F;
  • food. This includes a wider variety of materials found in homes; and
  • moisture.

If insufficient levels of any of these requirements exist, all mold growth will stop and fungi will go dormant. Most are difficult to actually kill.

Even though mold growth may take place in the attic, mold spores can be sucked into the living areas of a residence by low air pressure. Low air pressure is usually created by the expulsion of household air from exhaust fans in bathrooms, dryers, kitchens and heating equipment.

Improper Ventilation bath-fan-attic-termination

Ventilation ducts must be made from appropriate materials and oriented effectively in order to ensure that stale air is properly exhausted.

Ventilation ducts must:

  • terminate outdoors. Ducts should never terminate within the building envelope;
  • contain a screen or louvered (angled) slats at its termination to prevent bird, rodent and insect entry;
  • be as short and straight as possible and avoid turns. Longer ducts allow more time for vapor to condense and also force the exhaust fan to work harder;
  • be insulated, especially in cooler climates. Cold ducts encourage condensation;
  • protrude at least several inches from the roof;
  • be equipped with a roof termination cap that protects the duct from the elements; and
  • be installed according to the manufacturer’s recommendations.

The following tips are helpful, although not required. Ventilation ducts should:

  • be made from inflexible metal, PVC, or other rigid material. Unlike dryer exhaust vents, they should not droop; and
  • have smooth interiors. Ridges will encourage vapor to condense, allowing water to back-flow into the exhaust fan or leak through joints onto vulnerable surfaces.

Above all else, a bathroom ventilation fan should be connected to a duct capable of venting water vapor and odors into the outdoors. Mold growth within the bathroom or attic is a clear indication of improper ventilation that must be corrected in order to avoid structural decay and respiratory health issues.

This entry was posted in Attic, Heating, Ventilation and Air Conditioning. Bookmark the permalink.